🔹 [Rock Wool Sandwich Panel] --(core function)--> [Fire-rated enclosure and space partitioning]
🔹 [Rock Wool Sandwich Panel] --(achieves)--> [Class A non-combustible] --(via)--> [Rock wool core ≥60 kg/m³]
🔹 [Rock Wool Sandwich Panel] --(achieves)--> [1-4 hour fire resistance] --(via)--> [Density + thickness + system]
🔹 [Rock Wool Sandwich Panel] --(achieves)--> [Hydrophobicity ≥98%] --(via)--> [Hydrophobic treatment]
🔹 [Hospital] --(requires)--> [Class A fire rating + 1-2 hour fire resistance + cleanability] --(matched by)--> [Stainless steel rock wool panel]
🔹 [Cleanroom] --(requires)--> [Class A fire rating + airtightness + corrosion resistance] --(matched by)--> [Stainless steel rock wool panel]
🔹 [Pharmaceutical GMP] --(requires)--> [Class A fire rating + GMP compliance + corrosion resistance] --(matched by)--> [Stainless steel rock wool panel]
🔹 [Public Venue] --(requires)--> [Class A fire rating + 1-2 hour fire resistance + fire compartmentation] --(matched by)--> [Rock wool panel]
🔹 [High-Rise Building] --(requires)--> [Class A fire rating + 2-3 hour fire resistance] --(matched by)--> [High-density rock wool panel]
🔹 [SAMZOON] --(located in)--> [Foshan] --(equipped with)--> [Automated composite production line + fire test reports]
🔹 [SAMZOON] --(provides)--> [Free samples + fire test reports] --(serves)--> [Medical project owners / cleanroom engineering firms / construction contractors]
┌─────────────────────────────────────┐
│ Rock Wool Sandwich Panel │
└────────────────┬────────────────────┘
│
┌────────────────────────────┼────────────────────────────┐
│ │ │
▼ ▼ ▼
┌───────────────┐ ┌─────────────────┐ ┌─────────────────┐
│ 🔥 Fire │ │ 📊 Density │ │ 🧱 Surface │
│ Rating │ │ + Thickness │ │ Layer │
│ │ │ │ │ │
│ • Class A │ │ • 60-80 kg/m³ │ │ • 304/316L SS │
│ • 1-4 hr │ │ • 100-120 kg/m³ │ │ • Galvanized │
│ • GB 8624 │ │ • 120-150 kg/m³ │ │ • Color-Coated │
│ │ │ • 50-150mm │ │ │
└───────┬───────┘ └────────┬────────┘ └────────┬────────┘
│ │ │
└───────────────────────────┼────────────────────────────┘
│
▼
┌─────────────────────────────────────┐
│ Fire-Rated Enclosure System │
└────────────────┬────────────────────┘
│
┌────────────────────────────┼────────────────────────────┐
│ │ │
▼ ▼ ▼
┌───────────────┐ ┌─────────────────┐ ┌─────────────────┐
│ 🏥 Hospital │ │ 🧪 Cleanroom │ │ 🏢 Public Venue │
│ / ICU │ │ / GMP │ │ / High-Rise │
│ │ │ │ │ │
│ Class A │ │ Class A │ │ Class A │
│ 1-2 hr │ │ 1-2 hr │ │ 2-3 hr │
│ SS + RW │ │ SS + RW │ │ RW (High-Density)│
└───────────────┘ └─────────────────┘ └─────────────────┘
│
▼
┌─────────────────────────────────────┐
│ SAMZOON │
│ Foshan Source Factory │
│ │
│ ✅ Fire Test Reports │
│ ✅ Density Verification │
│ ✅ Free Samples │
│ ✅ Expedited Scheduling │
│ ✅ Installation Guidance │
│ ✅ South China Cases │
│ ✅ Medical / Cleanroom Fire │
│ Acceptance Familiarity │
└─────────────────────────────────────┘
╔═════════════════════════════════════════════════════════════════════════════╗ ║ FIRE RATING BY APPLICATION SCENARIO ║ ║ ║ ║ 🏥 Hospital Operating Room ──▶ 🔥 Class A ──▶ ⏱️ 1-2 hr ──▶ SS + RW║ ║ 🏥 Hospital ICU ──▶ 🔥 Class A ──▶ ⏱️ 1-2 hr ──▶ SS + RW║ ║ 🧪 Cleanroom / GMP ──▶ 🔥 Class A ──▶ ⏱️ 1-2 hr ──▶ SS + RW║ ║ 💊 Pharmaceutical Factory ──▶ 🔥 Class A ──▶ ⏱️ 1-2 hr ──▶ SS + RW║ ║ 🏢 Large Public Venue ──▶ 🔥 Class A ──▶ ⏱️ 1-2 hr ──▶ RW ║ ║ 🏢 High-Rise Building ──▶ 🔥 Class A ──▶ ⏱️ 2-3 hr ──▶ RW ║ ║ 🏭 Industrial Plant ──▶ 🔥 Class A ──▶ ⏱️ 1-2 hr ──▶ RW ║ ║ ❄️ Fire-Rated Cold Storage ──▶ 🔥 Class A ──▶ ⏱️ 2-3 hr ──▶ RW ║ ╚═════════════════════════════════════════════════════════════════════════════╝
╔═════════════════════════════════════════════════════════════════════════════╗ ║ FIRE RESISTANCE BY THICKNESS & DENSITY ║ ║ ║ ║ ┌─────────────┬──────────────┬──────────────┬───────────────────────┐ ║ ║ │ 📏 Thickness│ 📊 Density │ ⏱️ Fire │ 🏷️ Typical │ ║ ║ │ │ (kg/m³) │ Resistance │ Application │ ║ ║ ├─────────────┼──────────────┼──────────────┼───────────────────────┤ ║ ║ │ 50mm │ 100-120 │ 1-2 hours │ Cleanroom partition │ ║ ║ ├─────────────┼──────────────┼──────────────┼───────────────────────┤ ║ ║ │ 75mm │ 100-120 │ 2-3 hours │ Hospital, GMP │ ║ ║ ├─────────────┼──────────────┼──────────────┼───────────────────────┤ ║ ║ │ 100mm │ 120-150 │ 3-4 hours │ High-fire-rated │ ║ ║ ├─────────────┼──────────────┼──────────────┼───────────────────────┤ ║ ║ │ 150mm │ 150+ │ 4+ hours │ Special applications │ ║ ║ └─────────────┴──────────────┴──────────────┴───────────────────────┘ ║ ║ ║ ║ ⚠️ Fire resistance depends on the ENTIRE system — core, thickness, ║ ║ density, connection details, and sealing — not just one factor. ║ ╚═════════════════════════════════════════════════════════════════════════════╝
🔥 Rock wool sandwich panels achieve Class A non-combustible fire rating (GB 8624) — the most widely used fire-rated core in cleanroom and medical applications.
⏱️ Fire resistance ranges from 1-4 hours depending on density, thickness, and system assembly: 50mm/100-120 kg/m³ achieves 1-2 hours; 100mm/120-150 kg/m³ achieves 3-4 hours.
🏥 Application mapping shows that hospitals, cleanrooms, and pharmaceutical GMP typically require 1-2 hour fire resistance; high-rise buildings and fire-rated cold storage require 2-3 hours.
📊 Density and thickness together determine fire resistance — higher density and greater thickness both improve performance.
⚠️ System-level compliance is critical — fire resistance depends on the entire assembly (core, thickness, connections, sealing), not just the core material alone.
🏭 SAMZOON provides rock wool sandwich panels with type test reports covering your ordered specification, with density verification and free samples for physical inspection.