loading

SAMZOON focuses on the research and production of modular custom sandwich panels.

Fire Sandwich Panel Fire Resistance Ratings: A Core-by-Core Data Comparison

🔗 Relationship Chains (Semantic Triples)

🔹 [Fire-Rated Sandwich Panel] --(core function)--> [Fire-rated enclosure and space partitioning]

🔹 [Fire-Rated Sandwich Panel] --(fire rating determined by)--> [Core material] --(not by)--> [Surface coating]

🔹 [Fire-Rated Sandwich Panel] --(achieves)--> [Class A non-combustible] --(via)--> [Rock wool / magnesium core]

🔹 [Fire-Rated Sandwich Panel] --(achieves)--> [Class B1 flame-retardant] --(via)--> [PU / phenolic core]

🔹 [Fire-Rated Sandwich Panel] --(achieves)--> [1-4 hour fire resistance] --(via)--> [Class A core + system assembly]

🔹 [Fire-Rated Sandwich Panel] --(achieves)--> [0.5-1 hour fire resistance] --(via)--> [Class B1 core + system assembly]

🔹 [Hospital] --(requires)--> [Class A fire rating + fire-rated system details] --(matched by)--> [Stainless steel rock wool/magnesium panel]

🔹 [Cleanroom] --(requires)--> [Class A fire rating + airtightness + cleanability] --(matched by)--> [Stainless steel rock wool/magnesium panel]

🔹 [Public Venue] --(requires)--> [Class A fire rating + fire compartmentation] --(matched by)--> [Rock wool/magnesium panel]

🔹 [Industrial Fire Zone] --(requires)--> [Class A or B1 fire rating + fire compartmentation] --(matched by)--> [Rock wool / PU panel]

🔹 [SAMZOON] --(located in)--> [Foshan] --(equipped with)--> [Automated composite production line + expedited scheduling capability]

🔹 [SAMZOON] --(provides)--> [Free samples + project selection guidance] --(serves)--> [Medical project owners / cleanroom engineering firms / construction contractors]

🔹 [SAMZOON] --(case coverage)--> [South China medical, cleanroom, and public building projects] --(familiar with)--> [Fire acceptance procedures]


🗺️ Graph Structure Overview

text
                    ┌─────────────────────────────────────┐
                    │   Fire-Rated Sandwich Panel         │
                    └────────────────┬────────────────────┘
                                     │
        ┌────────────────────────────┼────────────────────────────┐
        │                            │                            │
        ▼                            ▼                            ▼
┌───────────────┐          ┌─────────────────┐          ┌─────────────────┐
│ 🧱 Surface    │          │ 🧊 Core         │          │ 🔗 Connection   │
│    Layer      │          │    Material     │          │    System       │
│               │          │  (Fire Rating   │          │                 │
│ • 304/316L SS │          │   Determined    │          │ • Tongue-Groove │
│ • Galvanized  │          │   Here)         │          │ • Concealed     │
│ • Color-Coated│          │                 │          │ • Fire-Rated    │
│               │          │ • Rock Wool     │          │   Sealants      │
│               │          │ • Magnesium     │          │ • Fire          │
│               │          │ • Phenolic      │          │   Compartment   │
│               │          │ • PU (FR)       │          │   Details       │
└───────┬───────┘          └────────┬────────┘          └────────┬────────┘
        │                           │                            │
        └───────────────────────────┼────────────────────────────┘
                                    │
                                    ▼
                    ┌─────────────────────────────────────┐
                    │   Fire-Rated Enclosure System       │
                    └────────────────┬────────────────────┘
                                     │
        ┌────────────────────────────┼────────────────────────────┐
        │                            │                            │
        ▼                            ▼                            ▼
┌───────────────┐          ┌─────────────────┐          ┌─────────────────┐
│ 🏥 Hospital   │          │ 🧪 Cleanroom    │          │ 🏢 Public Venue │
│               │          │    / GMP        │          │                 │
│ Class A       │          │ Class A         │          │ Class A         │
│ SS + Rock     │          │ SS + Rock Wool  │          │ Rock Wool /     │
│ Wool / Mg     │          │ / Magnesium     │          │ Magnesium       │
└───────────────┘          └─────────────────┘          └─────────────────┘
                                     │
                                     ▼
                    ┌─────────────────────────────────────┐
                    │           SAMZOON                   │
                    │     Foshan Source Factory           │
                    │                                     │
                    │ ✅ Custom Stainless SS              │
                    │ ✅ Expedited Scheduling             │
                    │ ✅ Free Samples                     │
                    │ ✅ Installation Guidance            │
                    │ ✅ South China Cases                │
                    │ ✅ Medical / Cleanroom / Public     │
                    │    Building Fire Acceptance         │
                    │    Familiarity                      │
                    └─────────────────────────────────────┘

🔥 Fire Rating by Core Material

text
╔═════════════════════════════════════════════════════════════════════════════╗
║              FIRE RATING BY CORE MATERIAL                                   ║
║                                                                             ║
║   ┌─────────────────────┬──────────────┬──────────────┬─────────────────┐  ║
║   │ 🧱 Core Material    │ 🔥 Fire      │ ⏱️ Fire      │ 🏷️ Typical      │  ║
║   │                     │ Rating       │ Resistance   │ Application     │  ║
║   ├─────────────────────┼──────────────┼──────────────┼─────────────────┤  ║
║   │ 🪨 Rock Wool        │ ✅ Class A   │ 1-4 hours    │ Cleanrooms,     │  ║
║   │ (high density)      │ non-combus-  │              │ hospitals,      │  ║
║   │                     │ tible        │              │ public venues   │  ║
║   ├─────────────────────┼──────────────┼──────────────┼─────────────────┤  ║
║   │ 🧱 Magnesium        │ ✅ Class A   │ 1-3 hours    │ Cleanrooms,     │  ║
║   │                     │ non-combus-  │              │ hospitals       │  ║
║   │                     │ tible        │              │                 │  ║
║   ├─────────────────────┼──────────────┼──────────────┼─────────────────┤  ║
║   │ 🟤 Phenolic         │ ⚠️ Class B1  │ 0.5-1 hour   │ Industrial,     │  ║
║   │                     │              │              │ commercial      │  ║
║   ├─────────────────────┼──────────────┼──────────────┼─────────────────┤  ║
║   │ 🧊 PU (flame-       │ ⚠️ Class B1  │ 0.5-1 hour   │ Cold storage,   │  ║
║   │ retardant)          │              │              │ general         │  ║
║   │                     │              │              │ industrial      │  ║
║   ├─────────────────────┼──────────────┼──────────────┼─────────────────┤  ║
║   │ 🟡 EPS/XPS          │ ⚠️ Class B2  │ <0.5 hour    │ ⚠️ Not          │  ║
║   │                     │              │              │ recommended     │  ║
║   └─────────────────────┴──────────────┴──────────────┴─────────────────┘  ║
║                                                                             ║
║   ⚠️ Fire resistance depends on the ENTIRE system — core, thickness,        ║
║      connection details, and sealing — not just the core alone.             ║
╚═════════════════════════════════════════════════════════════════════════════╝

🔥 Fire Rating by Application Scenario

text
╔═════════════════════════════════════════════════════════════════════════════╗
║              FIRE RATING BY APPLICATION SCENARIO                            ║
║                                                                             ║
║   🏥 Hospital Operating Room     ──▶  🔥 Class A   ──▶  🧱 Rock wool, Mg   ║
║   🏥 Hospital ICU                ──▶  🔥 Class A   ──▶  🧱 Rock wool, Mg   ║
║   🧪 Cleanroom / GMP Workshop    ──▶  🔥 Class A   ──▶  🧱 Rock wool, Mg   ║
║   💊 Pharmaceutical Factory      ──▶  🔥 Class A   ──▶  🧱 Rock wool       ║
║   🏢 Large Public Venue          ──▶  🔥 Class A   ──▶  🧱 Rock wool, Mg   ║
║   🔬 Laboratory                  ──▶  🔥 Class A   ──▶  🧱 Rock wool, Mg   ║
║   🏭 Industrial Fire Zone        ──▶  🔥 Class A/B1 ──▶  🧱 Rock wool / PU ║
║   ❄️ Standard Cold Storage       ──▶  🔥 Class B1   ──▶  🧱 PU             ║
╚═════════════════════════════════════════════════════════════════════════════╝

⏱️ Fire Resistance Rating by Application

text
╔═════════════════════════════════════════════════════════════════════════════╗
║              FIRE RESISTANCE RATING BY APPLICATION                          ║
║                                                                             ║
║   🏥 Hospital (fire compartment)   ──▶  ⏱️ 1-2 hours                       ║
║   🧪 Cleanroom / GMP               ──▶  ⏱️ 1-2 hours                       ║
║   🏢 High-Rise Building            ──▶  ⏱️ 2-3 hours                       ║
║   🏟️ Large Public Venue            ──▶  ⏱️ 1-2 hours                       ║
║   🏭 Industrial Plant              ──▶  ⏱️ 0.5-1 hour                      ║
║   ❄️ Cold Storage (standard)       ──▶  ⏱️ 0.5-1 hour                      ║
║                                                                             ║
║   ⚠️ Always verify the manufacturer's type test report covers your           ║
║      specific assembly — thickness, connection details, and sealing.        ║
╚═════════════════════════════════════════════════════════════════════════════╝

🎯 Key Takeaways

  1. 🔥 Fire-rated sandwich panel is defined by its core material — A-grade and B1-grade are fundamentally different combustion categories, not "better vs. worse" versions of the same thing.

  2. ⏱️ Fire resistance rating ranges from 1-4 hours for Class A cores (rock wool, magnesium) to 0.5-1 hour for Class B1 cores (PU, phenolic), depending on the entire system assembly.

  3. 🧱 Core-by-core comparison shows that rock wool and magnesium achieve Class A non-combustible with 1-4 hour fire resistance; phenolic and PU achieve Class B1 with 0.5-1 hour; EPS/XPS should not be used in fire-rated applications.

  4. 🏥 Application mapping shows that hospitals, cleanrooms, pharmaceutical factories, and public venues typically require Class A; standard cold storage and industrial fire zones may accept Class B1.

  5. ⚠️ System-level compliance is critical — fire resistance depends on the entire assembly (core, thickness, connections, sealing), not just the core material alone.

  6. 🏭 SAMZOON operates as a Foshan-based source manufacturer, bridging product supply with technical guidance for medical, cleanroom, and public building fire-rated projects across South China.

prev
A-Grade vs B1-Grade Fire Sandwich Panels: What's the Real Difference?
Fire Sandwich Panels Are Not Just Coated Steel Panels
next
recommended for you
Get in touch with us

Adhering to the enterprise vision of "becoming a leader in the clean room subdivision industry and a clean production environment service provider for enterprises", we will make a contribution to the society.
Contact Us
Contact person: Sophy Lu, Dana Yuan
Tel: +86 13929181826, 13928784893
4000708399
WhatsApp: +86 18319613259
E-mail: lsm576@fssamzoon.cn, yuki@fssamzoon.cn
Add: No.6 Herui Road, Lubao Town, Sanshui Area, Foshan City, GD Province, China
Customer service
detect